主な機能

  • Integrates Echelon’s LNS network management engine, which has been used in more than 90,000 systems to commission more than 5 million devices
  • Provides a software platform for Windows that can be used to develop or run Windows applications for designing, installing, monitoring, or controlling IzoT and LON networks
  • Supports LonTalk/IP and ISO/IEC 14908-1 LON compatible devices including LonTalk/IP and IP-852 devices on Ethernet or Wi-Fi channels, as well as LonTalk/IP and classic LON devices on ISO/IEC 14908-2 FT, ISO/IEC 14908-3 PL, or RS-485 channels
  • Provides an open platform supporting multiple simultaneous users commissioning, monitoring, and operating devices and running multiple applications from multiple vendors
  • Supports a wide variety of applications including network management applications, operator interface applications, drivers, and network diagnostic tools
  • Supports IzoT Net, OpenLNS, and LNS plug-ins
  • Supported by hundreds of third-party applications
  • Supports networks with up to 32,385 devices on up to 1000 channels, with each device supporting up to 4096 data points or network variables
  • Supports multi-channel networks with multiple LonTalk/IP, classic LON, and IP-852 routers
  • Free trial edition is available for download
  • Trial edition may be freely redistributed with applications and plug-ins

Tech Specs

Specifications
PC Requirements:

Operating System

  • Microsoft Windows 8 (64-bit and 32-bit), Windows 7(64-bit and 32-bit), Windows Server 2012 (64-bit),Windows Server 2008 R2 (64-bit), Windows Server 2008 with SP2 (32-bit), or Windows XP with SP3 (32-bit)

Minimum Hardware

  • Intel Pentium III 1.3 GHz processor or faster, and meeting the minimum Windows requirements for the selected version of Windows
  • 2 GB RAM
LonTalk/IP and LON Network Limits

Limits per Device (further limits may be imposed by device firmware)

  • 4096 datapoints or NVs per device
  • 32,768 address table entries
  • 1024 alias table entries

Limits per Network

  • 20 active clients
  • 32,385 devices (routers and network service devices count as two devices each)
  • 32,385 application device types
  • 1000 channels and 1000 routers
  • 1 domain
  • 12,288 bound selectors (selectors are automatically reused so the number of connections is not limited by this protocol limit)

Limits per IzoT Net Server

  • 100 network databases can be open simultaneously in independent mode for monitoring and control
  • 50 network databases can be open simultaneously for full IzoT network services including management, monitoring, and control
  • 8000 datapoints can be active with intelligent point sharing if multiple applications are monitoring the same point; this limit does not apply to permanent monitor point monitoring
  • 65,535 permanent monitor points; monitoring a local host network variable does not consume a persistent monitor point
  • 8000 permanent monitor sets; each monitor set may be used by any application
  • 250 simultaneous outgoing transactions (when using a native LonTalk/IP, IP-852, or LON Layer 2 network interface)
  • 250 simultaneous incoming transactions (when using a native LonTalk/IP, IP-852, or LON Layer 2 network interface)


IzoT Net Server Datasheet

ダウンロード

リソース

​See convergence of building and lighting systems into one.

知識キットへのアクセス

Why the Industrial IoT is Really Control Networking 2.0?